Power supply 40-50W with PFC with additional output 5V and 5V/GND (insulated from common GND)
|
Uin =95 – 270 VAC (50-60Hz)
|
Uout1 =42V DC (for RED) and Uout2=45V DC (for Blue and Green) with 3 values (Uout1+1V, +2V, Uout2+1V, +2Vselected by jumpers), tol. Uout =<2%
|
Pomax = max 50W, Eff > 85%
|
PFC - available up to 95% - input 90-270V AC, with THD< 5%
|
U Add. Output = 5V, P = 200 mW – (for insulated DMX In/Out signals interface and for insulated from the Main GND and Earth DMX signal shielding) insulated from the Main Output Uout /GND and from the Uin.
|
U Add. Output = 5V, P = 1-2 W – not insulated from the Main Output Uout
|
All the Output voltages are isolated from the primary main Uin by > 2000V transformer/optocoupler insulation
|
Input/Output Over Current protection
|
Output Short –Circuit protection
|
Overheating protection (Heat- Sink protection temperature >90 deg. C)
|
Additional output over voltage protection - 50V +/- 2%
|
Feeding voltage to the control box: single phase 230V AC, 50/60Hz or 12V DC, to be specified.
|
Feeding voltage to the unit : 12 V DC
|